Preiswertes Ethernet I/O Modul mit 12 Ein- und 8 Ausgängen. Improve system efficiency via real-time data acquisition Unlike traditional passive Ethernet I/O, Active Ethernet I/O provides Active I/O essaging that can send message over Ethernet, TCP/IP network on I/O input status changes or meets certain condition, the message is sent to host computer. Communication between the host computer and Active Ethernet I/O device is concise and efficient. In addition, the message delivery time is 20 times faster than traditional SCADA systems (50 ms compared to 1 sec).
Übersicht:

Improve system efficiency via real-time data acquisition
Unlike traditional passive Ethernet I/O, Active Ethernet I/O provides Active I/O essaging that can send message over Ethernet, TCP/IP network on I/O input status changes or meets certain condition, the message is sent to host computer. Communication between the host computer and Active Ethernet I/O device is concise and efficient. In addition, the message delivery time is 20 times faster than traditional SCADA systems (50 ms compared to 1 sec).
No programming! Hassle-free Click&Go™ logic control
Click&Go™ logic is the key to make ioLogik E2000 series become an intelligent Ethernet I/O. Click&Go™ logic lets you decide when to send I/O data, and what to say to host computers for simple alarm control and messaging.
As opposed to using C-language or PLC-ladder, a person who understands basic logic concepts can do the configuration themselves, and easily finish their projects. Unlike passive Ethernet I/O architecture, you can integrate Active Ethernet I/O’s input signals into one event to be an integrated message, and set up local output control at the same time. The unique Click&Go™ logic is a patent pending technology developed by Moxa.
Unique LCD Display Module for on-site configuration
ioLogik E2000 series Active Ethernet I/O provides an optional LCD display module for on-site management and configuration. The unique display module can display network and I/O settings, e.g. analog input value, digital input counter value. The IP, netmask address can be set locally without carrying a PC.

Independent Configuration for Multi-functional DI and DO points
Each digital input can be configured independently for DI or Event Counter mode, and each digital output can be independently configured for DO or Pulse Output mode.
Typical Application

Specifications
LAN: Ethernet 10/100 Mbps, RJ45
Protection: 1.5 KV magnetic isolation
Protocol: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O and Network), HTTP, SNTP,Active I/O Messaging, IP filtering
Serial Interface: RS-485 (2-wire): Data+, Data-, GND
Serial Line Protection: 15 KV ESD for all signals
Serial Communication Parameters: Parity None
Data bits: 8
Stop bits: 1
Flow control: None
Speed: 1200 bps to 115200 bps
Protocol: Modbus/RTU
Built-in RTC: Yes
Power Requirements
Power input: 24 VDC nominal, 12 to 48 VDC
Power consumption: 282 mA @ 24 VDC (typ.)
Field power: 24 VDC nominal, up to 48 VDC
Mechanical Specifications
Wiring: I/O cable max. 14 AWG
Environmental Operating temperature: -10 to 60°C (14 to 140°F), 5 to 95% RH
Storage temperature: -40 to 85°C (-40 to 185°F), 5 to 95%RH
Vibration: IEC60068-2-6
Digital Input
Inputs: 12, source type
I/O Mode: DI or Event Counter (up to 900 Hz)
Dry Contact: Logic 0: short to GND, Logic 1: open
Wet Contact: Logic 0: 0 to 3 VDC, Logic 1: 10 to 30 VDC (DI COM to DI)
Common type: 12 points / 1 COM
Isolation: 3000 VDC
Digital Output
Outputs: 8, sink type
I/O Mode: DO or Pulse output (up to 1 KHz)
On-state voltage: 24 VDC nominal
Output current rating: Max. 200 mA per channel
Optical isolation: 3K VDC
Protection
Over temperature shutdown: Min. 170°C
Over current limit: typ. 750 mA/channel
Agency Approvals
EMI: FCC Part 15, CISPR (EN55022) Class A
EMS: IEC61000-4-2 (ESD), level 2/3
IEC61000-4-3 (RS), level 2
IEC61000-4-4 (EFT), level 2
IEC61000-4-5 (Surge), level 3
IEC61000-4-6 (CS), level 2
IEC61000-4-8 (PM), level 1
IEC61000-4-11 (Dip)
Safety: UL 508
Shock: IEC60068-2-27
Freefall: IEC60068-2-32